How should one design a 50kHz, 1200VA
transformer
as per IEC 61558 ?
Technical specification relevant only to design
Electrical data and diagram
| Input voltages |
Max. 280Vac, square-wave |
| Frequency |
50kHz |
Nominal output voltage 1
Nominal output current 1 |
24Vac
10Aac |
Nominal output voltage 2
Nominal output current 2 |
24Vdc, bridge rectifier with R load
10Adc |
Nominal output voltage 3
Nominal output current 3 |
24Vdc, bridge rectifier with RL load
10Adc |
Nominal output voltage 4
Nominal output current 4 |
24Vdc, central tapping rectifier with R load
10Adc |
Nominal output voltage 5
Nominal output current 5 |
24Vdc, central tapping rectifier with RL load
10Adc |
Ambient and operating conditions:
| Ambient temperature |
40°C |
| Mode of operation |
Continuous |
| Test conditions |
Non inherently short-circuit proof |
Specification

Criteria for design
IEC 61558
A high-frequency transformer with non inherently short-circuit proof as per IEC 61558
is equipped with a safety. Very often we arrive at a combined protection solution
consisting of a thermal cutout in the transformer and cut-out electronics in the cycled
mains power unit to protect against overload and short-circuit. For this reason,
short-circuit and overload are not design criteria. The criterion for design with regard
to IEC 61558 is only temperature q nominal.
| Insulation class |
A |
E |
B |
F |
H |
| Max winding temperature in test q max (° C) |
200 |
215 |
225 |
240 |
260 |
| Max winding temperature in nominal operating
mode q nominal (° C) |
100 |
115 |
120 |
140 |
165 |
Insulation class
Max winding temperature in nominal operating mode = 115°C
Max winding temperature in test mode = 215°C
Insulation class E is prescribed.
Criterion for design
Normally, high-frequency transformers have very low regulation and are designed
according to the prescribed temperature rise.
Since these transformers are manufactured almost exclusively using ferrite, the optimum
operating temperature is around 100°C.
Bobbin unit
In order to protect the transistors, high-frequency transformers should be
manufactured for low scatter, with single-chamber bobbin units. For this reason, we very
often arrive at dual-wire or interleaved windings.
Ferrite quality
Since the optimum operating temperature of ferrite for high-frequency transformers
over 100VA is around 100°C and their ambient temperature is between 40°C and 70°C, our
design assumption must be for an temperature rise of between 30°K and 60°K. If the core
losses in relation to temperature rise are not economically acceptable, then the computer
program will optimise or reduce induction automatically. But this does indicate that the
selected ferrite quality is not optimized.
Induction and ferrite quality
High-frequency transformers are equipped almost exclusively with ferrite. The program
calculates both the active and the reactive core losses by hypothesizing the ferrite type,
the frequency, the form of input voltage, induction and core temperature. The induction
should be selected such that the transformer does not saturate at maximum input voltage
and maximum core temperature.
Copper additional losses
With a high-frequency transformer, the distinctions are drawn between the following
additional losses in a winding, over and above the dc-current losses:
- Eddy current losses
- Displacement losses
- Proximity effect losses
- Losses due to circulating currents through the parallel-connected wires.
Additional losses are smaller in the case of a winding that takes up only 30-60% of the
available winding space. For that reason, one should always set the input for the filling
factor between 0.3 and 0.6 for purposes of automatic core selection.
The input for Rac/Rdc will limit the extent of additional losses (eddy current
losses and displacement losses). The computer program selects a high enough number of
parallel-connected wires for the eddy current losses and displacement losses to fall short
of the prescribed value for Rac/Rdc. For that reason, the input for Rac/Rdc is
also used for monitoring of parallel-connected wires. The value is normally set between
1.5 and 5.
Proximity effects can be reduced by means of the Spread input. Another option for
reducing proximity effects is to select wires with thicker insulation.
Losses of circulating currents through the parallel-connected wires are not calculated. It
is assumed that these additional losses have been eliminated by suitable design
precautions. In particular, it should be ensured, for a given litz, that the twisting for
the winding is done such that a given wire has the same position at the input and at the
output of the winding.

Procedure for design
- If you are not yet acquainted with Rale design software, please read the text
"How should I design a small transformer?". Keep a copy of this text within
convenient reach whenever performing design work.
- Fill in the design input mask as follows. If you need any help, press function key F1.
There is extensive description for each input field.

- The Selection input field is set at 0. This means that the program should
search on-line for a suitable core for this application, from your selected core family.
- Save your input data file. In this specimen design calculation, we saved the input data
in input data file CAL0009E.TK1. This input data file was supplied together with
this document. Copy it into the directory in which your Rale demo program is installed.
- Connect up to the Rale design server.
- Load up your input data file.
- Now select the core family and the core for automatic search by the computer program.

- Click on OK.
- Start your design work. In the system for automatic selection of the core from your
prescribed core family, the program will offer you an adequately sized core for your
application. Click on OK in order to accept the core.

On completion of the design work, the following design data will be available and
can be printed on three pages:










- This is followed by checking of the design data.
- The program has reduced the entered induction from 0.2T to 0.172T. This is an indication
that at the selected induction of 0.2T, core losses would be too high by comparison with
copper losses. An improvement could be achieved by increasing the core cooling surface
area or by using a higher grade of ferrite.
- We now check the winding data and the filling factor (37.7%<100%).
- The maximum temperature of the windings is 40°C+58.25°K = 98.2°C < 115°C.
- The number of parallel-connected wires with 0.15 mm diameter is 66 and 161. Commercial
considerations prompt us to select a litz of 50 wires of 0.16 mm diameter for the primary
and a litz of 175 wires with 0.16 mm for all secondary windings. This operation must be
performed manually in the test mode.
- In the test mode, furthermore, the number of windings of the secondary is manually
rounded up from 1.9 to 2 turns. This will result in approximately 5% higher output
voltage.

- If the design data is not satisfactory, then there are two ways by which we can
implement the desired correction:
- You can return to the input mask (function key F2), correct the input data and redesign
the transformer.
- Or you can access the test program (function key F5), modify the designed transformer
manually and redesign the transformer by that means.
- On completion of the design work, you can print out the design data on-line, or save it
on your local PC and print it out off-line. The output data file from this design example,
CAL0009E.TK2, is supplied together with this document. Copy it
into the directory in which your Rale demo program is installed.
Tips & Tricks
Typical circuits

Upon entering the input voltage, we assume that there is an impressed voltage for
circuits 1, 2 & 3.
The input current for circuits 4, 5 & 6 is impressed. For these circuits, we have to
start by determining the primary input voltage, the secondary voltage and the secondary
current manually in order to be able to use the computer program to design the
transformer.
Circuits 7 to 10 are a combination of supply with impressed voltage and supply with
impressed current, and are treated as circuits with impressed current.
Copper strip instead of litz
A litz can be replaced by a copper strip. The strip thickness should correspond to the
wire diameter of the litz. Strip width should be matched to the width of the bobbin. The
number of strips connected in parallel is determined in accordance with the following
illustration.