How should one design
a 250kHz, 120W forward transformer with voltage controller, for input voltage range 200V
to 350V,
as per IEC 61558?
Technical specification relevant only to design
Electrical data and diagram:
| Input voltages range |
200Vdc - 350Vdc (bridge rectifier with RC-load, for input voltage
230Vac+10%-20%, 50Hz) |
| Frequency |
70kHz |
| Nominal output voltage |
2 x 12Vdc, automatic controlled on the primary side |
| Nominal output current |
2 x 5Adc, -50% |
| Ripple of the input current |
Max. 50% at the maximal input voltage and the nominal load |
Ambient and operating conditions:
| Ambient temperature |
40°C |
| Test conditions |
Non inherently short-circuit proof |
| Mode of operation |
Continuous |
Specification
Insulation class E
The following forward transformer diagram illustrates only parameters relating to
design. The windings for rekuperation and for measurement cannot be calculated by program.

During the initial half period a normal AC transformer is powered by positive voltage,
and during the second half period by negative voltage. The values of the voltage-time
surfaces of both voltages are the same. This changes the induction in the core of the AC
transformer from
-Bmax to +Bmax.
In the case of a forward transformer, the start of the primary development Wp during
the initial switching period q*T, which is not necessarily the same as the second
switching period, is fed to the input voltage Up. In this time the induction rises from Br
to Bmax. During the second switching period the end of the recuperation development Wr is
fed to the same input voltage. In this time the induction falls from Bmax to Br.
In this frequently-used forward transformer switch, magnetic energy stored during the
switch-on phase q*T is returned to the feed source via the feed source recuperation
development Wr. There are several layouts which can be used to realize the recuperation.
For this reason, and because the structural performance of this winding is normally only
approx. 10%-20% of the structural performance of the winding Wp, this winding is not
calculated with the program. The user calculates it manually.

In the case of forward transformers, one distinguishes between 2 main phases during a
switching period: during the first phase the primary voltage Up is fed to the
primary winding Wp. The primary voltage increases in direct proportion to the
voltage IL through the choke L. In addition comes the magnetizing voltage io.
The voltage lies in the secondary winding:
Us = (Uo+Udiode) / q.
During the second phase the primary winding WP is separated from the primary
voltage. The magnetic energy which is stored in this is returned via the winding Wr.
The number of windings Wr in this winding is chosen to ensure that the conditions:
q + r < 0.8-0.9
and
r = q * (Wr/Wp)
are constantly fulfilled. The relative switch-on duration q is chosen to be
between 0.40 and 0.60 at minimum input voltage. This produces:
r < 0.3 - 0.6
or
Wr = (0.5 - 0.66) * Wp
During the switching period T, the induction changes by pulsing between Br
and Bmax. The choice of Bmax depends on the ferrite type and on the
operating temperature. The residual induction Br can be set practically at a value
between 5% and 10% of the Bmax induction by an air gap in the core. With an
external source or a permanent magnet it would be possible to set a negative residual
induction.
The ripple of the voltage through the choke L affects the effective value of the
transformer voltage.
Ripple = 100 * (Ilmax-Ilmin)/Ilmax+Ilmin)
This value must be notified by the user.
Criteria for design
IEC 61558
A high-frequency transformer with non- inherently short-circuit proof as per IEC 61558 is
equipped with a safety. Very often we arrive at a combined protection solution consisting
of a thermal cutout in the transformer and cutout electronics in the cycled mains power
unit to protect against overload and short-circuit. For this reason, short-circuit and
overloads are not design criteria. The criterion for design with regard to IEC 61558 is
only temperature q nominal.
| Insulation class |
A |
E |
B |
F |
H |
| Max winding temperature in nominal operating mode q nominal (° C) |
100 |
115 |
120 |
140 |
165 |
Insulation class
Max winding temperature in nominal operating mode = 115°C
Insulation class E is prescribed.
Criterion for design
Normally, high-frequency transformers have very low regulation and are designed according
to the prescribed temperature rise.
Since these transformers are manufactured almost exclusively using ferrites, the optimum
operating temperature is around 100°C.
Bobbin unit
In order to protect the transistors, high-frequency transformers should be manufactured
for low leaking reactance, with single-chamber bobbin units. For this reason, we very
often arrive at bifilar or interleaved windings.
Ferrite quality
Since the optimum operating temperature of ferrite for high-frequency transformers over
100VA is around 100°C and their ambient temperature is between 40°C and 70°C, our
design assumption must be for a temperature rise of between 30°K and 60°K. If the core
losses in relation to temperature rise are not economically acceptable, then the computer
program will optimize or reduce the AC-component of the induction automatically. But this
does indicate that the selected ferrite quality is not optimized.
Induction and ferrite quality
High-frequency transformers are equipped almost exclusively with ferrites. The program
calculates both the active and the reactive core losses by hypothesizing the ferrite type,
the frequency, the form of input voltage, induction and core temperature. The induction
should be selected such that the transformer does not saturate at maximum input voltage
and maximum core temperature.
Copper additional losses
With a high-frequency transformer, the distinctions are drawn between the following
additional losses in a winding, over and above the dc-current losses:
- Eddy current losses
- Displacement losses
- Proximity effect losses
- Losses due to circulating currents through the parallel-connected wires.
Additional losses are smaller in the case of a winding that takes up only 30-60% of the
available winding space. For that reason, one should always set the input for the filling
factor between 0.3 and 0.6 for purposes of automatic core selection.
The input for Rac/Rdc will limit the extent of additional losses (eddy current
losses and displacement losses). The computer program selects a high enough number of
parallel-connected wires for the eddy current losses and displacement losses to fall short
of the prescribed value for Rac/Rdc. For that reason, the input for Rac/Rdc is
also used for monitoring of parallel-connected wires. The value is normally set between
1.5 and 5.
Proximity effects can be reduced by means of the Spread input. Another option for
reducing proximity effects is to select wires with thicker insulation.
Losses of circulating currents through the parallel-connected wires are not calculated. It
is assumed that these additional losses have been eliminated by suitable design
precautions. In particular, it should be ensured, for a given litz, that the twisting for
the winding is done such that a given wire has the same position at the input and at the
output of the winding.

Nominal input voltage and relative switch-on period
The relative primary voltage switch-on period is defined as follows:

In the design of a forward transformer, the duration of the relative switch-on period (q
= t1/(t1+t2) ) is taken into account indirectly via the input mode of the form
factor:
Form factor = 1/(2*q)
A forward transformer with an automatic controller of output voltage is normally
designed with the following parameters:
- "Nominal" input voltage Upmin = 200V.
- At this input voltage the relative switch-on period qmax will be 0.5 and the
relative recuperation period rmin = 0.35.
- The form factor = 1/(2* qmax) = 1/(2*0.5) = 1
- Th relative switch-on period at the input voltage Upmax = 350V will be:
qmin = qmax * Upmin/Upmax = 0.5 * 200 / 350 = 0.285
Procedure for design
- If you are not yet acquainted with Rale design software, please read the text
"How should I design a small transformer?". Keep a copy of this text within
convenient reach whenever performing design work.
- Fill in the design input mask as follows. If you need any help, press function keys F1.
There is extensive description for each input field.

- The Selection input field is set at 0. This means that the program should
search on-line for a suitable core for this application, from your selected core family.
- Save your input data file. In this specimen design calculation, we saved the input data
in input data file CAL0011E.TK1. This input data file was supplied together with
this document. Copy it into the directory in which your Rale demo program is installed.
- Connect up to the Rale design server.
- Load up your input data file.
- Now select the core family and the core for automatic search by the computer program.

- Click on OK.
- Start your design work. In the system for automatic selection of the core from your
prescribed core family, the program will offer you an adequately sized core for your
application. Click on OK in order to accept the core.
- On completion of your design work, the following design data is available. We must not
omit to mention at this point that the calculated data for short-circuit is not
applicable to the forward transformer (and cannot be used for that context).
- On completion of the design work, the following design data will be available,
which can be printed on 3 pages.









- Checking of the design data follows this.
- We now check the winding data and the filling factor (34.2%<100%).
- The maximum temperature of the windings is 40°C+57.1°K = 97.1°C < 115°C.
- The number of parallel-connected wires with 0.16 mm diameter is 6 and 27. Commercial
considerations prompt us to select a litz of 5 wires of 0.16 mm diameter for the primary
and a litz of 30 wires of 0.16mm for both secondary windings. This operation must be
performed manually in the test mode.
- There now follows the configuration of the recuperation winding Wr:
Wr = Wp * rmin/qmax= 23 * 0.285 / 0.5 = 13 windings
The number of parallel-switched wires is smaller than the number of parallel-switched
wires in the primary winding Wp by the factor Iporms/Iprms.
5 * 0.218/0.99= 1 wire
Iporms => No-load voltage
Iprms => Primary nominal voltage
- This is followed by checking of the output voltage for the maximal input voltage of 350V
and the relative switch-on period of 0.285: Uin = 350/200 = 1.75 and form factor =
1/(2*0.285) = 1.754.
Note that the program controls your input in order to avoid the operation in the
saturation of the core. If you get any problem with your input, follow these procedures.
- Increase the form factor to 1.754 (q = 0.285)
- Press F6 to recalculate
- Increase the input voltage to 350V : Uin = 1.75
- Press F6 to recalculate
or
- Decrease the input voltage to 200V : Uin = 1
- Press F6 to recalculate
- Decrease the form factor to 1.0 (q = 0.5)
- Press F6 to recalculate

The following table shows the summery of the most important parameters, calculated by
program in the test mode. Note that the relative switch-on period (q) was changed in order
to get the nominal input voltage as by a voltage controller.
Ui
V |
Iprms
A |
2xIsrms
A |
2xUodc
V |
2xIodc
A |
Pcu
W |
Pfe
W |
q |
Ripple
% |
dTcu
°K |
200 |
0.999 |
3.72 |
12.2 |
5.06 |
1.04 |
0.57 |
0.5 |
50 |
62.6 |
350 |
0.77 |
2.82 |
12.2 |
5.07 |
0.73 |
0.60 |
0.28 |
50 |
53 |
- If the design data is not satisfactory, then there are two ways by which we can
implement the desired correction:
- You can return to the input mask (function key F2), correct the input data and redesign
the transformer.
- Or you can access the test program (function key F5), modify the designed transformer
manually and redesign the transformer by that means.
- On completion of the design work, you can print out the design data on-line, or save it
on your local PC and print it out off-line. The output data file from this design example,
CAL0011E.TK2, is supplied together with this document. Copy it into the directory
in which your Rale demo program is installed.
Tips & Tricks
Rounding off the number of windings
With a flyback transformer, the procedure for rounding off the number of windings
differs from that employed with a "normal" transformer.
- Next, we correct the nominal primary voltage until the desired number of primary
windings is reached.
- In the test program, finally, the number of windings is rounded off manually.
Copper strip instead of litz
A copper strip can replace a litz. The strip thickness should correspond to the wire
diameter of the litz. Strip width should be matched to the width of the bobbin. The number
of strips connected in parallel is determined in accordance with the following
illustration.